Quick answer: A septic tank riser is a watertight collar that brings the tank's maintenance hole up to the surface, topped with a secured lid, so the tank can be found, pumped and checked without digging. Minnesota requires risers above final grade with locked, bolted, screwed or heavy lids on tanks built to its current rules (Minn. R. 7080.1970). North Dakota's state rule has manholes end 6 to 12 inches below grade unless the local authority allows them higher (N.D. Admin. Code 62-03.1-03-07).
Either way, a buried lid under frozen ground makes a routine pump-out much harder. Never go into a tank. For lid locating, risers or lid replacement in Cass and Clay County, call (701) 566-7446.
Last updated:
Why a buried lid is a bigger deal here
A septic tank can only be properly maintained through its lid, the University of Minnesota says, and on many older tanks that lid is buried. Once frost gets into the soil it is very difficult to dig down to it, so UMN recommends extending lids to grade to make pumping easier. Newer tanks have insulated maintenance lids at grade.
Red River Valley winters make the difference plain. If the tank backs up in January, or a high-water alarm goes off during a cold snap, someone has to find the lid under snow and then get through frozen ground to it. A riser turns that into brushing off snow and unscrewing a lid. It also helps the rest of the year: a fact sheet in EPA's Nonpoint Source Outreach Toolbox notes that risers help owners and inspectors find the tank and avoid digging up the lawn for every routine visit.
What a riser is, and what it isn't
The maintenance hole (often called the manhole) is the large opening in the top of the tank that the pumper uses. A riser is a section of pipe or collar, usually plastic, fiberglass or concrete, that sits on that opening and extends it upward, with a lid on top. The EPA toolbox fact sheet notes that plastic risers are watertight with bolted, lightweight lids, while concrete risers have heavy lids that are harder to lift and are not waterproof.
An inspection pipe is different. It is a small pipe, usually 4 to 6 inches across, over a baffle or a drain field, used to look at liquid levels. You can't pump a tank properly through it. Minnesota requires solids to be removed through the maintenance hole and says removal from anywhere else is not compliant (Minn. R. 7080.2450). The University of Minnesota tells homeowners to always have the tank cleaned through the manhole, the 20 to 24 inch opening, because the inspection pipes are just for inspection.
A riser should sit high enough to keep surface water out of the tank, UMN says, but there is no need for it to stick up so far that it becomes an eyesore or gets in the way of mowing. Spring melt and ponding are common on flat valley lots, so a riser that sits in a low spot or leaks at its joints can let water into the tank.
Minnesota rules (Moorhead, Dilworth and Clay County)
- Access openings. Septic tanks need at least two maintenance holes at least 20 inches across, one over the inlet baffle or the center of the tank and one over the outlet device, with enough openings to reach within six feet of every wall. Pump tanks need at least one (Minn. R. 7080.1970).
- Risers to the surface. All maintenance hole risers must extend through the tank cover above final grade (Minn. R. 7080.1970).
- Secure lids. Covers must be locked, bolted or screwed down, weigh at least 95 pounds, or use another method the local government approves. They must resist leaks, be designed so they can't be slid or flipped open, carry a written and graphic warning about the hazards inside, handle the load they are expected to get, and be made for outdoor use (Minn. R. 7080.1970).
- After every pump-out. On systems covered by the current rules, the lid must be secured again, with screws put back in every screw opening. On older systems, the lid has to be sound and either buried under at least 12 inches of soil or, if it is at or near the surface, secured. A lid that gets raised to grade has to meet the current cover rules (Minn. R. 7080.2450).
- Regular checks. Owners must have the tank assessed at least every three years, including whether tank tops, riser joints and riser connections leak (Minn. R. 7080.2450). An unsecured, damaged or weak maintenance hole cover is treated as an imminent threat to public health or safety (Minn. R. 7080.1500).
North Dakota rules (Fargo, West Fargo and Cass County)
North Dakota's state rule takes the opposite default. Septic tank manholes must be at least 18 inches across and within six feet of every wall of the tank. The manhole extends through the tank cover to a point 6 to 12 inches below finished grade, and the cover must be corrosion resistant, rated for a 300-pound load and buried under at least 6 inches of earth. A manhole can come up above grade only where the local authority allows it, and then it must be safely secured (N.D. Admin. Code 62-03.1-03-07). The tank also needs a 4-inch or larger inspection pipe, or a manhole, over both the inlet and outlet, capped flush with or above the ground. Pump chambers need a secure cover that is bolted on or heavy enough to prevent unauthorized entry (N.D. Admin. Code 62-03.1-03-11).
So on many Cass County properties a buried lid isn't a defect. It's what the state rule expects. If you want a riser brought to the surface, check with your local health authority first, and make sure the finished lid is secured.
Lid safety
- Never go into a septic tank, or lean in. UMN warns that a tank lacks oxygen and may contain dangerous gases. Keep kids and pets back whenever a lid is open.
- Keep every lid fastened. A plastic lid should have all its screws in. A lid that rocks, slides or is cracked needs replacing, not just setting back in place. UMN says children should not play on or around risers.
- Keep vehicles off. Lids are only built for the load they are expected to get. Don't park, plow or drive over the tank or lids.
- Watch for odor at the lid. A sewage smell at the tank often means a lid seal is worn. See our septic smell guide.
Winter: insulation, snow and cold air
A riser is a path for cold as well as for the pump hose. UMN says open, broken or uncapped risers, inspection pipes and manhole covers let cold air into the system and can cause it to freeze. It recommends tight covers on all of them and says insulation in the lids helps prevent heat loss through access points at grade. Before the snow comes, check that every lid and cap is tight, mark where the lids are, and leave the snow over the tank alone, since snow is insulation. More in winterizing a septic system and, if it is already too late, frozen septic system: what to do.
How risers tie into pumping and the effluent filter
Pumping is the main reason the lid has to come off. If yours is buried, it has to be found and exposed before the truck can do anything, which takes longer and gets much harder once the ground freezes. See septic tank pumping for how often and what a pump-out includes. If your tank has an effluent filter, it needs cleaning on its own schedule, often more often than the tank needs pumping. A riser over the outlet end makes that a short job.
Don't know where the tank is at all? Our guide on how to find your septic tank covers county as-built records, setback rules and safe probing.
Not sure where your lids are, or have a lid that is buried, cracked or loose? For lid locating, riser and lid work, or a pump-out in Cass and Clay County, call (701) 566-7446.
Frequently asked questions
Do I need risers on my septic tank?
In Minnesota, yes for any tank built to the current rules: maintenance hole risers must come up through the tank cover above final grade, with a secured, labeled lid (Minn. R. 7080.1970). On an older Minnesota tank, a lid that is raised to grade or within 12 inches of it has to meet those same cover requirements (Minn. R. 7080.2450). North Dakota's state rule is different. It has manholes end 6 to 12 inches below finished grade under at least 6 inches of earth, unless the local authority allows them above grade (N.D. Admin. Code 62-03.1-03-07). Even where they are optional, risers save digging every time the tank is pumped or checked.
Can a septic tank be pumped through the inspection pipe?
No. In Minnesota, solids have to be removed through the maintenance hole, and pumping from any other spot does not count as compliant solids removal (Minn. R. 7080.2450). The University of Minnesota says the same thing for homeowners: always have the tank cleaned through the manhole, the 20 to 24 inch opening. The small white inspection pipes are just for inspection. That is why the big lid has to be reachable, and why a riser over it matters.
How deep is a septic tank lid buried in North Dakota?
Under the state rule, the manhole stops between 6 and 12 inches below finished grade and the cover is buried under at least 6 inches of earth, unless the local authority allows it above grade (N.D. Admin. Code 62-03.1-03-07). Older tanks, regraded yards and landscaping can leave lids deeper than that. If you don't know where yours is, check old permit or pumping records, or ask your pumper to measure and note it at the next service.
Are septic risers safe around kids and pets?
They are when the lid is secured. Minnesota requires covers that are locked, bolted or screwed down, or weigh at least 95 pounds, that can't be slid or flipped open, and that carry a hazard warning label (Minn. R. 7080.1970). North Dakota requires a secure cover on pump chambers (N.D. Admin. Code 62-03.1-03-11). The University of Minnesota says children should not play on or around risers. Replace a cracked, loose or sunken lid right away, and never go into a septic tank.
Will a riser make my septic system freeze?
A tight, insulated lid shouldn't. What lets cold in is an opening. The University of Minnesota says open, broken or uncapped risers, inspection pipes and manhole covers let cold air into the system and can cause it to freeze. Keep every cover tight, and insulation in the lid helps prevent heat loss through an at-grade access. Newer tanks often come with insulated lids at grade. Leave the snow over the tank alone, since snow is insulation too.
Should I add a riser when I get my tank pumped?
That is the easiest time, because the lid is already dug out. A riser has to be sealed to the tank so it doesn't let water in, and the new lid has to be secured. In Minnesota, a lid raised to grade must meet the cover rules in Minn. R. 7080.1970. In North Dakota, ask your local health authority first, because the state rule expects buried manholes unless the local authority allows them above grade. A riser over the outlet end also makes it much easier to service an effluent filter.