Quick answer: When a septic alarm goes off, the water in the pump tank (or holding tank) has risen above its normal level. Silence the buzzer if the panel has a silence switch, cut water use to a minimum, check that the breaker for the septic pump hasn't tripped, and call the same day. The common causes are a tripped breaker, a failed pump, a stuck float switch, a clogged filter, a frozen line or a burst of heavy water use. For septic alarm service in Cass and Clay County, call (701) 566-7446.
Last updated:
What a septic alarm is
Many systems around Fargo–Moorhead can't send effluent downhill by gravity. Red River Valley clay and high water tables mean a lot of mound systems and pressure-distribution fields, and those need a pump. The pump sits in a pump tank (also called a dosing chamber or pump chamber) after the septic tank. Float switches inside tell it when to turn on and off. A separate float, set higher than the pump's "on" float, runs the alarm. If the level reaches that float, the pump isn't keeping up, and the University of Minnesota's training manual for septic professionals describes that alarm as a sign of a pump malfunction.
Minnesota makes the alarm mandatory. Its rules say a septic system with a pump must use an alarm device to warn of failure (Minn. R. 7080.2100). North Dakota's pump rules (N.D. Admin. Code 62-03.1-03-11) cover the pump chamber, the pump and its float switches but don't spell out an alarm, so an older Cass County system may or may not have one. If you have a pump and no alarm, it's worth adding one.
You may also see an alarm on two other setups. A septic tank with an effluent filter can have a high-water alarm that warns when the filter is clogging. Our effluent filter guide explains how to check and clean one. And a holding tank in Minnesota must have an alarm at 75 percent full unless it's pumped on a schedule (Minn. R. 7080.2290). There, the alarm just means it's time to pump.
What to do when the alarm goes off
- Silence it, don't disable it. Most control panels have a silence or test switch. Use that to quiet the buzzer. Don't unplug the panel or shut off the alarm circuit. You want to know if the level keeps rising.
- Cut water use right away. Flush only when needed. No laundry, no dishwasher, no baths, short showers. The space above the alarm float is a limited reserve, and how much there is depends on your tank.
- Check the breaker. Find the breaker or plug for the septic pump and see if it has tripped. If it trips again right after you reset it, leave it off and call. That points to an electrical or pump fault.
- Think about the last few hours. Several loads of laundry, a long day of guests, or a water softener recharge can send more water than the pump moves at once. If the pump is running and the alarm clears within a few hours, that may be all it was. Still mention it at your next service.
- Call the same day if the alarm doesn't clear, keeps coming back, or the breaker won't stay on. The University of Minnesota's owner guidance is simple: something is wrong when the alarm is activated, so call your service professional.
Common reasons a septic alarm sounds
- Tripped breaker or lost power. The pump can't run without power, but the alarm is often on its own circuit, so it still sounds. This is the cheapest fix and the first thing to check.
- Failed pump. Effluent pumps wear out over the years. A pump that hums but doesn't move water, or doesn't run at all with power on, needs replacing.
- Stuck or failed float switch. If the "on" float is tangled, stuck or dead, the pump never gets the signal. A float that sticks only sometimes causes an alarm that comes and goes.
- Clogged effluent filter or pump screen. A filter that hasn't been cleaned slows the flow. Depending on the setup, that can trip a high-water alarm on the septic tank or starve the pump.
- Frozen or blocked line. In a Fargo–Moorhead winter, the line from the pump to the mound can freeze. See the winter section below.
- Too much water at once. Heavy laundry days, leaking toilets or fixtures, and clear water that shouldn't be in the system all add gallons.
- Groundwater getting in. A tank or riser joint that leaks can let groundwater in during a wet spring or after heavy rain, raising the level faster than normal use would.
- A field or mound that isn't taking water. Less common, but if the pump runs and the level still won't drop, the problem may be downstream. See drain field and mound repair.
Septic alarms in winter
Cold weather adds its own causes. If you hear the pump running constantly in winter, the line to the mound or field may be frozen, with the same water draining back into the pump tank over and over. The University of Minnesota's advice in that case is to shut off the pump and call an onsite professional. That's different from an ordinary alarm, when you leave the system on and just cut water use. Also make sure the pump tank's lid stays reachable. UMN says a manhole on a tank with a pump must come to the surface so the pump can be repaired or replaced, and you may need it at any time of year. Mark it before snow falls.
For more, see frozen septic system: what to do and winterizing a septic system.
Preventing alarm calls
- Have the pump, floats and alarm checked when the tank is pumped. The University of Minnesota's training for septic professionals includes verifying that alarms work and that the homeowner knows what they mean.
- Test the alarm with the panel's test switch now and then, so you know it works before you need it.
- Clean the effluent filter on schedule, and pump the septic tank on time so solids don't reach the pump tank. See septic tank pumping.
- Spread out water use. A few loads of laundry over the week are easier on a pump system than all of them on Saturday. Fix running toilets and dripping faucets.
- Know where things are. Write down where the panel, the pump breaker and the pump tank lid are, and keep the lid at ground level.
If sewage is already backing up into the house, go to emergency septic service. For septic alarm and pump service in Cass and Clay County, call (701) 566-7446.
Frequently asked questions
Why is my septic alarm going off?
On most systems around Fargo–Moorhead, the alarm is a high-water float in the pump tank (the dosing chamber that feeds a mound or pressure field). It sounds when effluent rises above the level where the pump should already have turned on. The usual causes are a tripped breaker or lost power to the pump, a failed pump, a stuck or failed float switch, a clogged effluent filter or pump screen, a frozen or blocked line to the mound, or simply more water than the system can handle at once. On a holding tank, the alarm means the tank is about 75 percent full and needs pumping.
Is a septic alarm an emergency?
Treat it as an urgent same-day problem. Minnesota requires every septic system with a pump to have an alarm to warn of failure (Minn. R. 7080.2100), and the University of Minnesota's owner guidance is blunt: something is wrong when the alarm is activated, so call your service professional. The tank above the alarm float has only limited reserve space. Once that fills, sewage can back up into the lowest drains in the house or come out the top of the tank.
Can I turn off my septic alarm?
You can silence it, but don't ignore it. Most control panels have a silence or test switch that quiets the buzzer while the warning light stays on. Silencing it doesn't fix anything. Keep water use to a minimum and get the system checked the same day. Don't unplug the panel or switch off the alarm circuit, because then you won't know if the level keeps rising.
How long can I use water after the septic alarm goes off?
Only lightly, and not for long. How much reserve is left depends on the size of the pump tank and where the alarm float is set, and that varies by system. Flush only when necessary and skip laundry, the dishwasher, baths and long showers until the cause is found. If the alarm went off right after a big burst of water, like several loads of laundry, and the pump is running, it may clear on its own within a few hours. If it doesn't, call.
My septic alarm went off and then stopped. Do I still need to call?
Usually yes, at least to have it checked soon. An alarm that clears on its own can mean the pump caught up after a heavy water day, which is harmless. It can also mean a float that sticks now and then, a pump that is starting to fail, or groundwater leaking into the tank during a wet spell. If it happens more than once, have the pump, floats and alarm tested before it turns into a backup.
What does it mean if I hear the pump running constantly in winter?
It can be a sign the line to the mound or drain field is frozen and the pump is cycling water that drains straight back. The University of Minnesota's advice is to shut off the pump and call an onsite professional. Stop using water, and see our frozen septic system guide for what else to do.