Quick answer: A holding tank is a sealed, watertight tank with no drain field. It stores all the sewage from the building until a pump truck hauls it away. In the Fargo–Moorhead area holding tanks are permitted case by case, usually where a site can't support a drain field or mound, or for light seasonal use.
Minnesota requires an alarm at 75 percent full unless the tank is on a regular pumping schedule, and how often you pump depends on your water use and tank size. To set up holding tank pumping, call (701) 566-7446.
Last updated:
Holding tank vs. septic tank
A septic tank is the first stage of a treatment system. Solids settle to the bottom as sludge, grease floats to the top as scum, and the clearer liquid in the middle flows out to a drain field or mound, where the soil finishes the job. You pump a septic tank to remove the sludge and scum that build up over years.
A holding tank has no outlet to the soil at all. Minnesota's rules define it as a tank for storing sewage until it can be transported to a point of treatment and dispersal (Minn. R. 7080.1100). Everything that goes down every drain stays in the tank until it's pumped. So the pumping question changes. Instead of how fast sludge builds up, it becomes how many gallons a day the household sends to a tank of a given size. That is why a holding tank is a reasonable answer for a lightly used seasonal place and an expensive one for a busy year-round household, as our septic installation page puts it.
When holding tanks are used and allowed
Minnesota. Holding tanks are a recognized system type under Minn. R. 7080.2290, classed with floodplain systems and privies as Type II systems (Minn. R. 7080.2250). The state leaves the when to the counties. Every county SSTS ordinance must include a provision that specifies the conditions necessary to allow holding tanks, along with their operation and maintenance requirements (Minn. R. 7082.0100). In Clay County, that means Clay County Environmental Health decides whether a holding tank is allowed on a given property.
North Dakota. The state's onsite rules in N.D. Admin. Code chapter 62-03.1-03 don't have a separate holding-tank section. The baseline is that household wastewater passes through a septic tank before it goes into the soil or an alternative system, and that where underground disposal isn't feasible, consideration will be given to special methods of collection and disposal (N.D. Admin. Code 62-03.1-03-01). The rules also let alternative designs be submitted to the administrative authority for approval (62-03.1-03-12), and they don't stop local ordinances from applying (62-03.1-02-01). In Cass County, that authority is Fargo Cass Public Health, whose onsite system application lists a holding tank as its own permit category.
What Minnesota requires of a holding tank
Minn. R. 7080.2290 sets out the specifics. Most of it is about keeping the tank sealed and easy to pump:
- Watertight, and tested. Every tank used as a holding tank must be tested for watertightness. A holding tank that leaks lets sewage out and groundwater in, which can mean more trips for the pump truck.
- A 6-inch clean-out pipe. A clean-out pipe at least six inches across must reach the ground surface, with seals to stop odors and keep out insects and vermin.
- A maintenance hole. A maintenance hole at least 20 inches across must come up through the cover to within 12 inches of finished grade, but no closer than six inches below it. If there's less than six inches of soil over it, the cover has to be secured.
- Minimum size. For a home, at least 1,000 gallons or 400 gallons times the number of bedrooms, whichever is greater. Floodplain sites are sized differently. Compare that with septic tank minimums in our septic tank size guide.
- Truck access in all weather. The tank has to be located where a pump truck can reach it under all weather conditions, and where a spill during pumping won't create a nuisance. It also has to meet the state's setback distances.
- An alarm. Covered in the next section.
One pumping rule is different for holding tanks. For septic tanks and pump tanks, Minnesota says solids have to come out through the maintenance hole, and pumping through a small pipe doesn't count. For holding tanks, removing liquid and solids through the clean-out pipe is allowed (Minn. R. 7080.2450). Septic additives don't substitute for pumping under the same rule. See our septic tank additives guide.
High-water alarms
Minnesota requires a holding tank to have an alarm device to reduce the chance of an accidental overflow, unless the tank is pumped on a regular schedule. The alarm has to signal when the tank reaches 75 percent of capacity (Minn. R. 7080.2290). That leaves a reserve, not a cushion to live in. The University of Minnesota's holding-tank management plan says to have the tank emptied within 24 hours of the alarm and to make sure at least 25 percent reserve capacity remains.
- Check it daily. The UMN plan tells owners to monitor the alarm daily. Know whether yours is a light, a buzzer or both, and where it is.
- Test it. Ask the pumper to verify the alarm works at each visit. An alarm that never goes off may simply be broken.
- When it sounds: cut water use to a minimum (no laundry, no dishwasher, short showers), call for a pump-out, and don't keep resetting it.
How often a holding tank needs pumping
There is no 3-to-5-year rule for a holding tank. The schedule comes from two numbers: how big the tank is and how many gallons a day go into it. The University of Minnesota's management plan gives owners a starting estimate: tank capacity divided by the number of occupants times 50 gallons per day equals the number of days between pump-outs, or within 24 hours of the alarm, whichever comes first. By that estimate, two people on a 1,000-gallon tank would be looking at about 10 days. Your real number depends on your habits, so track the water meter for a while and adjust.
What moves the schedule, according to the same plan:
- People and occupancy. More people and more days at the property mean more gallons. A seasonal place used on weekends fills far more slowly than one lived in full-time.
- Water-using appliances. Garbage disposals, washing machines, dishwashers and big tubs all add gallons. Full loads, front-loading washers, short showers and skipping the disposal stretch the time between pump-outs.
- Clear water that shouldn't be there. Water softener and iron filter backwash, reverse osmosis reject water, footing drains and surface drainage aren't sewage, and the UMN plan says they shouldn't go into a holding tank. Reroute them where allowed, and set a softener to recharge by gallons used rather than by the calendar.
- Leaks. A running toilet or dripping faucet sends gallons to the tank around the clock. Check for leaks and fix them promptly.
Seasonal properties should be pumped at the end of the season. For regular septic tank pumping and scheduling, see septic tank pumping.
Winter access and frost
A holding tank can't wait for spring the way an ordinary septic tank sometimes can, so winter access is part of owning one. Minnesota's requirement that the tank be reachable by a pump truck in all weather is the starting point. The UMN plan adds a few frost habits:
- Keep a route open. Plow the driveway and a path the truck can use to reach the tank, and mark the clean-out and maintenance hole before snow covers them.
- Insulate the riser cover and inspect caps and lids every fall. Fix or replace damaged caps before winter to help prevent freezing.
- Stop the drips. A high-efficiency furnace that drains into the tank, or any other small steady trickle, can freeze in the line in cold weather. The UMN plan says not to route furnace condensate to a holding tank.
- Leave the snow over the tank alone. Loose, undisturbed snow insulates. Keep vehicles off the tank itself.
- Plan for vacancy. For a seasonal property, pump at the end of the season and work out a winter water-use plan so a visit doesn't turn into an emergency call.
More cold-weather prevention is in winterizing a septic system. If drains have already stopped, see frozen septic system: what to do.
Signs of trouble
- The alarm is sounding. The tank has hit the 75 percent mark. Cut water use and call for a pump-out. For pump-tank alarms on mound systems, see the septic alarm guide.
- The tank fills faster than it used to. If your water use hasn't changed, look for leaking fixtures, a clear-water source that got connected to the tank, or groundwater getting in through a leaking tank or riser joint, especially in a wet spring.
- The tank fills slower than your water use says it should. If the gallons pumped are well below what the water meter shows went down the drains, the tank may be leaking out. That's a problem to have checked.
- The alarm never goes off. It may be fine, or it may be dead. Have it tested.
- Odors or backups. A sewage smell near the tank or clean-out, or slow drains in the lowest fixtures, can mean a full tank, a failed seal or a frozen line.
If sewage is coming back into the house now, go to emergency septic service.
Permits and who to call
Installing, replacing or altering a holding tank goes through the local permitting office. In Cass County, ND, that's Fargo Cass Public Health's environmental health office. Its onsite system application covers holding tanks as their own category, says a permit is issued only on approval, and makes the work subject to inspection. The form also notes that individual sewage systems aren't permitted in a floodway hazard area. In Clay County, MN, Clay County Environmental Health administers Minnesota's SSTS rules, including the county's conditions for holding tanks. Minnesota recommends an operating permit for holding tanks (Minn. R. 7082.0100), so ask whether one applies to yours.
If your property might support a drain field or mound system, a soil evaluation is the way to find out, and a treatment system can cost less to live with than hauling every gallon. For ongoing holding tank pumping in Cass and Clay County, call (701) 566-7446.
Frequently asked questions
What is the difference between a holding tank and a septic tank?
A septic tank treats wastewater by letting solids settle and grease float, then sends the clearer liquid on to a drain field or mound. A holding tank has no drain field. It is a sealed, watertight tank that stores all the sewage from the house until a pump truck hauls it away for treatment somewhere else. That means the whole tank gets pumped, not just the sludge and scum, and it fills on a schedule set by how much water the household uses.
Are holding tanks allowed in North Dakota and Minnesota?
Yes, with a permit and only where the local permitting office allows them. In Minnesota, holding tanks are a recognized system type under Minn. R. 7080.2290, and each county's ordinance has to spell out the conditions for using one (Minn. R. 7082.0100). North Dakota's onsite rules don't have a separate holding-tank section. They require wastewater to go through a septic tank to a soil system, and they say special collection and disposal methods will be considered where underground disposal isn't feasible (N.D. Admin. Code 62-03.1-03-01). In Cass County, Fargo Cass Public Health handles holding-tank permits. In Clay County, it's Clay County Environmental Health.
How often does a holding tank need to be pumped?
It depends almost entirely on water use and tank size, so it can be weeks or days, not years. The University of Minnesota's holding-tank management plan uses a planning estimate of the tank's capacity divided by the number of people times 50 gallons per day, or within 24 hours of the alarm, whichever comes first. Track your water meter for a few weeks to learn your real number, and keep at least 25 percent of the tank in reserve.
What should I do when my holding tank alarm goes off?
Cut water use to the minimum right away and call for a pump-out. Minnesota requires the alarm to signal when the tank reaches 75 percent of capacity, so the alarm is warning you that the reserve space is being used up, not that the tank has already overflowed. The University of Minnesota's guidance is to have the tank emptied within 24 hours of the alarm. Don't keep silencing it and hope it lasts until the weekend.
Can a holding tank be pumped in the middle of winter?
Yes, as long as the truck can get to it. Minnesota requires holding tanks to sit where a pump truck can reach them in all weather. In practice, keep the driveway and a path to the tank plowed, mark the clean-out or maintenance-hole location before snow falls, and keep the riser cover insulated and its caps intact. Leave the snow over the tank itself loose and undisturbed. Don't let a high-efficiency furnace drip into the tank, because that steady trickle can freeze in the pipe.
Do I need a pumping contract for a holding tank?
In Minnesota, usually yes. State rules require county ordinances to include, at a minimum, a monitoring and disposal contract between the owner and a licensed maintenance business, with an exception for certain farmers. The owner is responsible for making sure the contract gets the tank emptied before it overflows (Minn. R. 7082.0100). In Cass County, check the permit conditions with Fargo Cass Public Health. Either way, a standing schedule is cheaper and calmer than emergency calls.